Skip to main content

DC 12V to AC 220V Modified Sine Wave Inverter


This inverter circuit can convert 12 volt DC voltage into AC voltage of 220 volts with a Modified Sine waveform or better known as the “Modified Sine Wave Inverter”. This inverter circuit has a modified sine wave output, so it has a better power efficiency than an inverter with square wave inverter type. Inverter circuit “Modified Sine Wave” is simple enough to be made, this inverter circuit built using the IC LM555 astable multivibrator, jonhson STP36No6L counter CD4017 and MOSFET as a power inverter. And a complete range of components to make a list Modified Sine Wave inverter can be seen in the following figure.

DC 12V to AC 220V Modified Sine Wave Inverter Circuit Diagram

DC 12V to AC 220V Modified Sine Wave Inverter Circuit Diagram

 Above the inverter circuit comprises a square wave generator (IC LM555) with a working frequency of 200Hz is used as a clock input johnson counter IC CD4017 as a modifier to be used as a square wave signal so that the output MOSFET drivers STP36N06L transformers form a modified sine wave. Step-up transformer at the inverter circuit is 10 volt CT transformer that serves to raise the DC voltage into AC voltage modified 220 volt with a modified sine wave output.

So that the output of the inverter circuit “Modified Sine Wave” above has an AC output frequency 50 Hz it is necessary to setup the waveform generator circuit. Working frequency setting is done by adjusting the potentiometer lever 500 Kohm on bagina wave generator (IC LM555) to provide output frequency 200Hz. Setting LM555 IC wave generator frequency to 200 Hz because by johnson counter with a pulse frequency of 200 Hz is used to establish the condition of pulse step 4 MOSFET driver to STP36N06L so that the inverter output frequency to 50 Hz.


Comments

Popular posts from this blog

TDA2030 complete tone control

At this time I present a series of amplifiers that use IC TDA2030, but this series is equipped with a tone control. Tone controls include Bass, Treebel, and Volume. Power amplifier and tone control has been put together in a single PCB. As well as its power supply circuit was also used as one with the power amp, and tone control. Making it easier in the installation and will look neat. Schematics Layout PCB PCB design This amplifier is a mono amplifier type, can be modif for guitar amplifiers. If not coupled amplifier (mic preamp) then you must deactivated potensio treble and bass, why? because if not using a mic preamp and still maintain potensio treble and bass sound input (input) from the guitar will not or the maximum discharge is not tight on the speakers. So you must deactivated a way to decide which directly connected capacitor with the tone control circuit, and capacitor were connected directly to potensio volume and input jack.

PID instruction in Allen Bradley PLC Closed Loop Control

PID instruction in Allen Bradley PLC [Proportional/Integral/Derivative] Closed Loop Control For   Processor SLC 5/02SLC 5/03SLC 5/04SLC 5/05    MicroLogix 1200 and MicroLogix 1500 (A special PID file replaces the old integer file control block.) Description of PID in PLC   This output instruction is used to control physical properties such as temperature, pressure, liquid level, or flow rate of process loops. The PID instruction normally controls a closed loop using inputs from an analog input module and providing an output to an analog output module as a response to effectively hold a process variable at a desired set point. The PID equation controls the process by sending an output signal to the actuator. The greater the error between the setpoint and the process variable input, the greater the output signal, and vice versa. An additional value (feed forward or bias) can be added to the control output as an offset. The result of the PID calculation (control vari...

NE566 Function Generator Circuit Diagram

The NE566 Function Generator is a Voltage-Controlled Oscillator of exceptional linearity with buf fered square wave and triangle wave outputs. The frequency of oscillation is determined by an external resistor and capacitor and the voltage applied to the control terminal. The Oscillator CAN be programmed over a ten-to-one frequency range by proper selection of an external resistance and modulated over a ten-to-one range by the control voltage, with exceptional linearity.  FMAX = 1 MHz     WIDE 1000:1 Continuous Sweep Possible  NE566 Function Generator Circuit Diagram Pdf Datasheet  Sourced by : Circuitsstream