Difference between Delta PLC EH2 series and EH3


Difference between Delta PLC EH2 series and EH3

  •   The capacity of the Ladder program is upgraded to 30k Steps, and the number of D devices is increased to 12000.
·        The capacity of the memory card has doubled. To prevent the wrong insertion, the new memory card and the old one are not interchangeable·         Some function cards of DVP-EH2 PLC can not be used in DVP-EH3. The function cards which can be used are all communication cards, 02AD card and 02DA card.·         When the position of the basic instruction is below 16k Step, the execution speed does not make any change.·        When its position is above 16k Step, the execution speed becomes 2.8μs.·         The execution speed of MOV instruction is improved to 4.8μs, and that of other application instructions is also improved by 4~5 times.·        The high-speed input/output functions of DVP-EH3 PLC




  1. The number of external input interruptions is 16.
  2.  There are 3 sets of masking functions of the interruption.
  3. Newly added CSFO instruction has the speed-tracing function and can be used with the manual pulse generator.  
  4. Newly added DVSPO and DICF instructions have various speed-changing functions. (Please refer to API 198 and API 199.)
  5. The zero return instruction (DZRN) has the function of detecting limit switches, stopping at the positive position, seeking Z phase, and outputting the displacement. (Please refer to API 156.)
  6. The direction outputs of DZRN instruction are used with Y1, Y3, Y5, and Y7. (Please refer to API 156.)
  7. That special M can set the start and reset functions of C235~C240 is cancelled. The bandwidth of C235~C240can be up to 10 KHz.

Other new functions of DVP-EH3 Series PLC

A.    COM1 card and COM3 card can be masters. COM3 is an independent communication port which does not occupy COM2. The flag of the transmitting function in the master is the same as that in DVP-ES2.
B.    The solar energy instructions DSPA and GPS instruction are added. (Please refer to API 177 and API 178)
C.     We add the m servo convenience instruction ASDRW. (Please refer to API 206.)
D.    The program can be automatically backed up, and will not disappear even if the battery has run down.
E.     The second-backup function can store the second program and data.
F.     We add the basic instructions which are used exclusively for words. For example, BLD, BOUT, and etc.(Please refer to API 266~274)
G.    The comparison instruction of the floating point number (FLD>=….).is added. (Please refer to API 275~292)
H.    M1356 can be used in PLC-LINK to designate the station numbers. Only when M1353 is on can D1900~D1931 be used.
I.       ISPSoft and WPLSoft can set the read-only function of the communication and function of downloading the program.

J.       It can connect with at most 12 right-side analog extension modules.

Comments

Popular posts from this blog

PID instruction in Allen Bradley PLC Closed Loop Control

PID instruction in Allen Bradley PLC [Proportional/Integral/Derivative] Closed Loop Control For   Processor SLC 5/02SLC 5/03SLC 5/04SLC 5/05    MicroLogix 1200 and MicroLogix 1500 (A special PID file replaces the old integer file control block.) Description of PID in PLC   This output instruction is used to control physical properties such as temperature, pressure, liquid level, or flow rate of process loops. The PID instruction normally controls a closed loop using inputs from an analog input module and providing an output to an analog output module as a response to effectively hold a process variable at a desired set point. The PID equation controls the process by sending an output signal to the actuator. The greater the error between the setpoint and the process variable input, the greater the output signal, and vice versa. An additional value (feed forward or bias) can be added to the control output as an offset. The result of the PID calculation (control vari...

NE566 Function Generator Circuit Diagram

The NE566 Function Generator is a Voltage-Controlled Oscillator of exceptional linearity with buf fered square wave and triangle wave outputs. The frequency of oscillation is determined by an external resistor and capacitor and the voltage applied to the control terminal. The Oscillator CAN be programmed over a ten-to-one frequency range by proper selection of an external resistance and modulated over a ten-to-one range by the control voltage, with exceptional linearity.  FMAX = 1 MHz     WIDE 1000:1 Continuous Sweep Possible  NE566 Function Generator Circuit Diagram Pdf Datasheet  Sourced by : Circuitsstream

Long Loopstick Antenna Circuit Diagram

Circuit Diagram  Description Wound on a 3 foot length of PVC pipe, the long loopstick antenna was an experiment to try to improve AM radio reception without using a long wire or ground. It works fairly well and greatly improved reception of a weak station 130 miles away. A longer rod antenna will probably work better if space allows. The number of turns of wire needed for the loopstick can be worked out from the single layer, air core inductance formula: Inductance = (radius^2 * turns^2) / ((9*radius)+(10*length)) where dimensions are in inches and inductance is in microhenrys. The inductance should be about 230 microhenrys to operate with a standard AM radio tuning capacitor (33-330 pF). The 3 foot PVC pipe is wound with approximately 500 evenly spaced turns of #24 copper wire which forms an inductor of about 170 microhenrys, but I ended up with a little more (213uH) because the winding spacing wasn't exactly even. A secondary coil of about 50 turns is wound along the length of th...