Troubleshooting STR IC Regulator Power Supply



A. Unable to start.
Can be caused by:
  • No start-up voltage supply Vcc or a voltage less than 16V
  • Electrolityc Capacitors supply voltage Vcc filter dry.

  
2. Led indicator blinking
If the supply voltage Vcc examined rocking. This is because the regulator of life and death because OVLO work., Die-protectionist regulators and auto start life over and over. If it is turned off Electrolityc Capacitors  usually still keep the rest of the cargo.
Can be caused by:

  • Electrolityc Capacitors supply voltage Vcc filter on a pin-4 dry. Replace with a value equal to or slightly larger. - triger UVLO
  • input filter capacitor on pin-1 feed dry behind the declining value - triger OLP
  • Rectifier diode of the switching transformer is damaged (sometimes when examined with avo-meter looks like a still good)
  • cause the supply voltage Vcc drops of the switching transformer (UVLO)
  • Part damage or broken lines on the feedback circuit of the voltage regulator through B to photocoupler - triger OVP
  • Electrolityc Capacitors dry filter voltage B - triger OVP
  • One of the output voltage of the switching transformer secondaries there is a short (over load) - triger OLP
  • Soft start capacitor value decreases - triger OLP

3. Noise arising (noise)
Can be caused by:

  • Transformer windings slack.
  • If there are ceramic capacitors - can sometimes cause interference noise due to its characteristic piezoelectrik like crystal resonator. Replace with film capacitors.

4. When the st-by normal stress. But when the power is on the regulator directly off protectionism no voltage on the secondary this part. Electrolityc Capacitors  are still storing charge.
Can be caused by:

  • Sensor OVP small value resistor on pin-2 to the ground so that the value of delayed triger to OLP or OCP.
  • Regulator IC is damaged

---------------------------------------------------------------------------------------------------------------------------
Note: Be careful when the regulator is not working. Because of Electrolityc Capacitors  may still have a charge when turned off.

Comments

Popular posts from this blog

PID instruction in Allen Bradley PLC Closed Loop Control

PID instruction in Allen Bradley PLC [Proportional/Integral/Derivative] Closed Loop Control For   Processor SLC 5/02SLC 5/03SLC 5/04SLC 5/05    MicroLogix 1200 and MicroLogix 1500 (A special PID file replaces the old integer file control block.) Description of PID in PLC   This output instruction is used to control physical properties such as temperature, pressure, liquid level, or flow rate of process loops. The PID instruction normally controls a closed loop using inputs from an analog input module and providing an output to an analog output module as a response to effectively hold a process variable at a desired set point. The PID equation controls the process by sending an output signal to the actuator. The greater the error between the setpoint and the process variable input, the greater the output signal, and vice versa. An additional value (feed forward or bias) can be added to the control output as an offset. The result of the PID calculation (control vari...

NE566 Function Generator Circuit Diagram

The NE566 Function Generator is a Voltage-Controlled Oscillator of exceptional linearity with buf fered square wave and triangle wave outputs. The frequency of oscillation is determined by an external resistor and capacitor and the voltage applied to the control terminal. The Oscillator CAN be programmed over a ten-to-one frequency range by proper selection of an external resistance and modulated over a ten-to-one range by the control voltage, with exceptional linearity.  FMAX = 1 MHz     WIDE 1000:1 Continuous Sweep Possible  NE566 Function Generator Circuit Diagram Pdf Datasheet  Sourced by : Circuitsstream

Long Loopstick Antenna Circuit Diagram

Circuit Diagram  Description Wound on a 3 foot length of PVC pipe, the long loopstick antenna was an experiment to try to improve AM radio reception without using a long wire or ground. It works fairly well and greatly improved reception of a weak station 130 miles away. A longer rod antenna will probably work better if space allows. The number of turns of wire needed for the loopstick can be worked out from the single layer, air core inductance formula: Inductance = (radius^2 * turns^2) / ((9*radius)+(10*length)) where dimensions are in inches and inductance is in microhenrys. The inductance should be about 230 microhenrys to operate with a standard AM radio tuning capacitor (33-330 pF). The 3 foot PVC pipe is wound with approximately 500 evenly spaced turns of #24 copper wire which forms an inductor of about 170 microhenrys, but I ended up with a little more (213uH) because the winding spacing wasn't exactly even. A secondary coil of about 50 turns is wound along the length of th...